V4 outdoor unit fault codes:

  • E0 – Communication error between outdoor units Displayed only on the auxiliary unit.  Read More
  • E1 – Phase sequence error Displayed on all outdoor units. Read More
  • E2 – Communication failure between master outdoor unit and indoor units Displayed on all outdoor units.
  • E4 – Outdoor unit temperature sensor failure Displayed on all outdoor units.
  • E8 – Outdoor unit addressing error Displayed on all outdoor units.
  • E9 – Supply voltage failure Displayed on all outdoor units.
  • H0 – Communication failure between DSP and 780.034 Displayed on all outdoor units.
  • H1 – Communication failure between 9177 and 780.034 Displayed on all outdoor units.
  • H2 – Decrease in number of outdoor units Only displayed on the main unit.
  • H3 – Increasing the number of outdoor units Only displayed on the main unit.
  • P0 – Inverter compressor protection Displayed on all outdoor units.
  • P1 – High pressure protection Displayed on all outdoor units.
  • P2 – Low pressure protection Displayed on all outdoor units.
  • P3 – Compressor overcurrent protection Displayed on all outdoor units.
  • P4 – Compressor discharge pipe overtemperature protection Displayed on all outdoor units.
  • P5 – Outdoor unit condenser high temperature protection Displayed on all outdoor units.
  • P6 – Inverter module protection Displayed on all outdoor units.
  • P7 – Constant compressor No. 1 overcurrent protection Displayed on all outdoor units.
  • P8 – No.2 constant compressor high current protection is displayed on 14 / 16HP outdoor units

V4 Outdoor Unit Central Control System Fault Codes:

  • H3 – Auxiliary outdoor unit increase error (Only displayed on the master unit)
  • H2 – Auxiliary outdoor unit decrease error (Only displayed on the master unit)
  • H1 – Communication failure
  • Ef – Other malfunction
  • E4t4 – Ambient or pipe temperature sensor malfunction
  • E3 – Ambient or pipe temperature sensor malfunctionı
  • E2 – Sensor Malfunction
  • E1 – Fault or missing phase during phase Read More
  • E0 – Communication Failure Read More
  • Pf – Other Protections
  • Pe – Oil Balancing
  • Pd – Oil return
  • Pa – Defrost Protection
  • P8 – 3. Compressor Current Protection
  • P7 – 2. Compressor Current Protection
  • P5 – Condenser high temperature protection
  • P4 – Compressor outlet temperature protection
  • P3 – Inverter compressor current protection
  • P2 – Low pressure protection
  • P1 – High pressure protection
  • P0 – Inverter compressor protection

V4 Plus Outdoor Unit Fault Codes :

  • E0 – Communication failure between outdoor units Read More
  • E1 – Phase sequence error DRead More
  • E2 – Communication failure between outdoor unit and indoor units
  • E4 – Ambient or pipe temperature sensor malfunction
  • E8 – Outdoor unit address setting error
  • E9 – Voltage error
  • H0 – Communication Failure between IR341 and 780034
  • H1 – Communication Failure between 0537 and 780034
  • H2 – Auxiliary outdoor unit decrease error
  • H3 – Auxiliary outdoor unit increase error
  • H4 – If P6 is displayed 3 times within half an hour, H4 is displayed.
  • H5 – If P2 is displayed 3 times in half an hour, H5 is displayed.
  • H6 – If P4 occurs 3 times in 100 minutes, refer to P4.
  • H9 – If P9 occurs 3 times in 30 minutes, see P9.
  • H7 – The number of indoor units does not match.
  • P0 – Inverter compressor temperature protection
  • P1 – High pressure protection
  • P2 – Low pressure protection
  • P3 – Inverter compressor current protection
  • P4 – Compressor outlet temperature protection
  • P5 – Condenser high temperature protection
  • P6 – Inverter module protection
  • P7 – 1. Constant compressor current protection
  • P8 – 2. Constant compressor current protection
  • P9 – Fan module protection
  • L0 – Inverter module protection
  • L1 – DC power supply low voltage
  • L2 – DC power supply high voltage
  • L4 – MCE error
  • L5 – Zero speed protection
  • L7 – Phase sequence error
  • L8 – The frequency is 15 Hz at one time. surplus
  • L9 – Protection: If the speed change set by instantaneous speed is & gt; 15Hz